External and Forest Fire Tanks

  • External and Forest Fire Tanks
  • External and Forest Fire Tanks

Our DECI or Firefighter tanks are very widely used for firefighting. External fire protection (DECI) consists of public or private fire-fighting water points that can be used to supply firefighting equipment with water. It's in this context and thanks to our experience with storage solutions and fire regulations that we offer you our DECI APRO Industry tanks.

Product Highlights
  • Reliable, robust and durable
  • Numerous possible standards of dimensions
  • Standardised equipment adapted for use by firefighters
  • Customisable for better landscape integration
  • Usable in any climatic conditions

The DECI, DFCI or APRO Industrie fire-fighting tanks

Our bolted tanks consist of a bolting assembly of galvanised steel panels. They comply with the regulations in force (national reference DECI, Regulation department DECI, NFS 62-240) 

Tanks adapted to all DECI needs

Municipalities, ZACs, agricultural buildings, public establishments (ERP), logistics companies or industrial buildings, we have a wide range of dimensions and volumes up to 10,000 m3 that will meet the requirements of the site and firefighters.

Technical characteristics of our DECI, DFCI or Retardant firefighter tanks

Manufactured by assembling S450 G350 galvanised steel panel bolted with 8.8 grade bolts in galvanized steel, our tanks are circular and adaptable in terms of diameter and height.

The sealing of the tank is ensured by a reinforced PVC liner. 

Our tanks are equipped with:

  • One or more standardised DN fireman direct sockets for connection by the SDIS to the suction
  • One or more suction intake(s) on the side or at the bottom in case of aspiration by a pump unit dedicated to the supply of fire poles 
  • A suction connection from the bottom for connection to an underground gravity distribution network on blue suction fire poles.

Standards and certifications for DECI, DFCI firefighting tanks.

Our tanks comply with the DECI standard and departmental regulation (RDDECI).

They meet the standards NFS61-240, NFS62-240 and the standards of French and international firefighters and fire and rescue services (SDIS).

 

Do you have a project?

Are you working on a project requiring the installation of a DECI/ DFCI tank? Contact our team for personalised advice!

What are the available sizes?

We offer tanks from 5 to 10,000m3 for outdoor fire protection and the provision of extinguishing water for firefighters. Many dimensions in diameter and height are available. Consult us!